All L3 Routed packets destined to virtual endpoints in the datacenter managed by ODL do not carry a proper source-mac address in such frames put out to virtual endpoints.
This spec makes sure a proper source-mac is updated in the packet at the point where the packet is delivered to the VM, regardless of the tenant network type. On the actual datapath, there will be no change in the source mac-addresses and packets continue to use the same mechanism that is used today.
Addressing the datapath requires unique MAC allocation per OVS Datapath, so that it can be used as the source MAC for all distributively routed packets of an ODL enabled cloud. It would be handled in some future spec.
Today all L3 Routed packets destined to virtual endpoints in the datacenter either
This spec is intended to setup a source-mac-address in the frame of L3 Routed packets just before such frames are directed into the virtual endpoints themselves. This enables use-cases where certain virtual endpoints which are VNFs in the datacenter that are source-mac conscious (or mandate that src-mac in frames be valid) can become functional on their instantiation in an OpenDaylight enabled cloud.
All the L3 Forwarded traffic today reaches the VM via a LocalNextHopGroup managed by the VPN Engine (including FIBManager).
Currently the LocalNextHopGroup sets-up the destination MAC Address of the VM and forwards the traffic to EGRESS_LPORT_DISPATCHER_TABLE (Table 220). In that LocalNextHopGroup we will additionally setup source-mac-address for the frame. There are two cases to decide what source-mac-address should go into the frame:
The implementation also applies to Extra-Routes (on a router) and Discovered Routes as they both use the LocalNextHopGroup in their last mile to send packets into their Nexthop VM.
We need to note that when a network is already part of a BGPVPN, adding a subnet on such a network to a router is disallowed currently by NeutronVPN. And so the need to swap the mac-addresses inside the LocalNextHopGroup to reflect the subnet gatewayip port here does not arise.
For all the use-cases listed in the USE-CASES section above, proper source mac address will be filled-up in the frame before it enters the virtual endpoint.
There are no pipeline changes.
The only change is in the NextHopGroup created by VPN Engine (i.e., VRFEntryListener). In the NextHopGroup we will additionally fill up the ethernet source mac address field with proper mac-address as outlined in the ‘Proposed change’ section.
Currently the LocalNextHopGroup is used in the following tables of VPN Pipeline:
cookie=0x8000002, duration=50.676s, table=20, n_packets=0, n_bytes=0, priority=10,mpls,mpls_label=70006 actions=write_actions(pop_mpls:0x0800,group:150000)
cookie=0x8000003, duration=50.676s, table=21, n_packets=0, n_bytes=0, priority=42,ip,metadata=0x222f2/0xfffffffe,nw_dst=10.1.1.3 actions=write_actions(group:150000)
cookie=0x9011176, duration=50.676s, table=36, n_packets=0, n_bytes=0, priority=5,tun_id=0x11176 actions=write_actions(group:150000)
NEXTHOP GROUP:
group_id=150000,type=all,bucket=actions=set_field:fa:16:3e:01:1a:40->eth_src,set_field:fa:16:3e:8b:c5:51->eth_dst,load:0x300->NXM_NX_REG6[],resubmit(,220)
None.
None.
None.
Carbon/Boron
None.
Primary assignee:
Other contributors:
No new dependencies.
Verify the Source-MAC-Address setting on frames forwarded to Virtual endpoints in following cases.
Intra-Datacenter traffic to VMs (Intra/Inter subnet).
Inter-Datacenter traffic to/from VMs.
N/A.
N/A.
N/A