VNI based L2 switching, L3 forwarding and NATing¶
https://git.opendaylight.org/gerrit/#/q/topic:vni-based-l2-l3-nat
Important: All gerrit links raised for this feature will have topic name as vni-based-l2-l3-nat
This feature attempts to realize the use of VxLAN VNI (Virtual Network Identifier) for VxLAN
tenant traffic flowing on the cloud data-network. This is applicable to L2 switching, L3
forwarding and NATing for all VxLAN based provider networks. In doing so, it eliminates the
presence of LPort tags, ELAN tags and MPLS labels on the wire and instead, replaces
them with VNIs supplied by the tenant’s OpenStack.
This will be selectively done for the use-cases covered by this spec and hence, its
implementation won’t completely remove the usage of the above entities. The usage of LPort tags
and ELAN tags within an OVS datapath (not on the wire) of the hypervisor will be retained, as
eliminating it completely is a large redesign and can be pursued incrementally later.
This spec is the first step in the direction of enforcing datapath semantics that uses tenant supplied VNI values on VxLAN Type networks created by tenants in OpenStack Neutron.
Note: The existing L3 BGPVPN control-path and data-path semantics will continue to use L3 labels on the wire as well as inside the OVS datapaths of the hypervisor to realize both intra-dc and inter-dc connectivity.
Problem description¶
OpenDaylight NetVirt service today supports the following types of networks:
- Flat
- VLAN
- VxLAN
- GRE
Amongst these, VxLAN-based overlay is supported only for traffic within the DataCenter. External network accesses over the DC-Gateway are supported via VLAN or GRE type external networks. For rest of the traffic over the DC-Gateway, the only supported overlay is GRE.
Today, for VxLAN enabled networks by the tenant, the labels are generated by L3 forwarding service and used. Such labels are re-used for inter-DC use-cases with BGPVPN as well. This does not honor and is not in accordance with the datapath semantics from an orchestration point of view.
This spec attempts to change the datapath semantics by enforcing the VNIs (unique for every VxLAN enabled network in the cloud) as dictated by the tenant’s OpenStack configuration for L2 switching, L3 forwarding and NATing.
This implementation will remove the reliance on using the following (on the wire) within the DataCenter:
- Labels for L3 forwarding
- LPort tags for L2 switching
More specifically, the traffic from source VM will be routed in source OVS by the L3VPN / ELAN pipeline. After that, the packet will travel as a switched packet in the VxLAN underlay within the DC, containing the VNI in the VxLAN header instead of MPLS label / LPort tag. In the destination OVS, the packet will be collected and sent to the destination VM through the existing ELAN pipeline.
In the nodes themselves, the LPort tag will continue to be used when pushing the packet from
ELAN / L3VPN pipeline towards the VM as ACLService continues to use LPort tags.
Simiarly ELAN tags will continue to be used for handling L2 broadcast packets:
- locally generated in the OVS datapath
- remotely received from another OVS datapath via internal VxLAN tunnels
LPort tag uses 8 bits and ELAN tag uses 21 bits in the metadata. The existing use of both in the metadata will remain unaffected.
In Scope¶
Since VNIs are provisioned only for VxLAN based underlays, this feature has in its scope the use-cases pertaining to intra-DC connectivity over internal VxLAN tunnels only.
On the cloud data network wire, all the VxLAN traffic for basic L2 switching within a VxLAN network and L3 forwarding across VxLAN-type networks using routers will use tenant supplied VNI values for such VXLAN networks.
Inter-DC connectivity over external VxLAN tunnels is covered by the EVPN_RT5 spec.
Out of Scope¶
- Complete removal of use of
LPort tagseverywhere in ODL: Use ofLPort tagswithin the OVS Datapath of a hypervisor, for streaming traffic to the right virtual endpoint on that hypervisor (note: not on the wire) will be retained - Complete removal of use of
ELAN tagseverywhere in ODL: Use ofELAN tagswithin the OVS Datapath to handle local/remote L2 broadcasts (note: not on the wire) will be retained - Complete removal of use of
MPLS labelseverywhere in ODL: Use ofMPLS labelsfor realizing an L3 BGPVPN (regardless of type of networks put into such BGPVPN that may include networks of type VxLAN) both on the wire and within the OVS Datapaths will be retained. - Addressing or testing IPv6 use-cases
- Intra DC NAT usecase where no explicit Internet VPN is created for VxLAN based external provider networks: Detailed further in Intra DC subsection in NAT section below.
Complete removal of use of LPort tags, ELAN tags and MPLS labels for VxLAN-type
networks has large scale design/pipeline implications and thus need to be attempted as future
initiatives via respective specs.
Use Cases¶
This feature involves amendments/testing pertaining to the following:
L2 switching use cases¶
- L2 Unicast frames exchanged within an OVS datapath
- L2 Unicast frames exchanged over OVS datapaths that are on different hypervisors
- L2 Broadcast frames transmitted within an OVS datapath
- L2 Broadcast frames received from remote OVS datapaths
L3 forwarding use cases¶
- Router realized using VNIs for networks attached to a new router (with network having pre-created VMs)
- Router realized using VNIs for networks attached to a new router (with new VMs booted later on the network)
- Router updated with one or more extra route(s) to an existing VM.
- Router updated to remove previously added one/more extra routes.
NAT use cases¶
The provider network types for external networks supported today are:
- External VLAN Provider Networks (transparent Internet VPN)
- External Flat Networks (transparent Internet VPN)
- Tenant-orchestrated Internet VPN of type GRE (actually MPLSOverGRE)
Following are the SNAT/DNAT use-cases applicable to the network types listed above:
- SNAT functionality.
- DNAT functionality.
- DNAT to DNAT functionality (Intra DC)
- FIP VM to FIP VM on same hypervisor
- FIP VM to FIP VM on different hypervisors
- SNAT to DNAT functionality (Intra DC)
- Non-FIP VM to FIP VM on the same NAPT hypervisor
- Non-FIP VM to FIP VM on the same hypervisor, but NAPT on different hypervisor
- Non-FIP VM to FIP VM on different hypervisors (with NAPT on FIP VM hypervisor)
- Non-FIP VM to FIP VM on different hypervisors (with NAPT on Non-FIP VM hypervisor)
Proposed change¶
The following components within OpenDaylight Controller needs to be enhanced:
- NeutronVPN Manager
- ELAN Manager
- VPN Engine (VPN Manager, VPN Interface Manager and VPN Subnet Route Handler)
- FIB Manager
- NAT Service
Pipeline changes¶
L2 Switching¶
Unicast¶
Within hypervisor¶
There are no explicit pipeline changes for this use-case.
Across hypervisors¶
Ingress OVS
Instead of setting the destination LPort tag, destination network VNI will be set in the
tun_idfield inL2_DMAC_FILTER_TABLE(table 51) while egressing the packet on the tunnel port.The modifications in flows and groups on the ingress OVS are illustrated below:
cookie=0x8000000, duration=65.484s, table=0, n_packets=23, n_bytes=2016, priority=4,in_port=6actions=write_metadata:0x30000000000/0xffffff0000000001,goto_table:17 cookie=0x6900000, duration=63.106s, table=17, n_packets=23, n_bytes=2016, priority=1,metadata=0x30000000000/0xffffff0000000000 actions=write_metadata:0x2000030000000000/0xfffffffffffffffe,goto_table:40 cookie=0x6900000, duration=64.135s, table=40, n_packets=4, n_bytes=392, priority=61010,ip,dl_src=fa:16:3e:86:59:fd,nw_src=12.1.0.4 actions=ct(table=41,zone=5002) cookie=0x6900000, duration=5112.542s, table=41, n_packets=21, n_bytes=2058, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,17) cookie=0x8040000, duration=62.125s, table=17, n_packets=15, n_bytes=854, priority=6,metadata=0x6000030000000000/0xffffff0000000000 actions=write_metadata:0x700003138a000000/0xfffffffffffffffe,goto_table:48 cookie=0x8500000, duration=5113.124s, table=48, n_packets=24, n_bytes=3044, priority=0 actions=resubmit(,49),resubmit(,50) cookie=0x805138a, duration=62.163s, table=50, n_packets=15, n_bytes=854, priority=20,metadata=0x3138a000000/0xfffffffff000000,dl_src=fa:16:3e:86:59:fd actions=goto_table:51 cookie=0x803138a, duration=62.163s, table=51, n_packets=6, n_bytes=476, priority=20,metadata=0x138a000000/0xffff000000,dl_dst=fa:16:3e:31:fb:91 actions=set_field:**0x710**->tun_id,output:1
Egress OVS
On the egress OVS, for the packets coming in via the internal VxLAN tunnel (OVS - OVS),
INTERNAL_TUNNEL_TABLEcurrently matches on destination LPort tag for unicast packets. Since the incoming packets will now contain the network VNI in the VxLAN header, theINTERNAL_TUNNEL_TABLEwill match on this VNI, set the ELAN tag in the metadata and forward the packet toL2_DMAC_FILTER_TABLEso as to reach the destination VM via the ELAN pipeline.The modifications in flows and groups on the egress OVS are illustrated below:
cookie=0x8000001, duration=5136.996s, table=0, n_packets=12601, n_bytes=899766, priority=5,in_port=1,actions=write_metadata:0x10000000001/0xfffff0000000001,goto_table:36 cookie=0x9000004, duration=1145.594s, table=36, n_packets=15, n_bytes=476, priority=5,**tun_id=0x710,actions=write_metadata:0x138a000001/0xfffffffff000000,goto_table:51** cookie=0x803138a, duration=62.163s, table=51, n_packets=9, n_bytes=576, priority=20,metadata=0x138a000001/0xffff000000,dl_dst=fa:16:3e:86:59:fd actions=load:0x300->NXM_NX_REG6[],resubmit(,220) cookie=0x6900000, duration=63.122s, table=220, n_packets=9, n_bytes=1160, priority=6,reg6=0x300actions=load:0x70000300->NXM_NX_REG6[],write_metadata:0x7000030000000000/0xfffffffffffffffe,goto_table:251 cookie=0x6900000, duration=65.479s, table=251, n_packets=8, n_bytes=392, priority=61010,ip,dl_dst=fa:16:3e:86:59:fd,nw_dst=12.1.0.4 actions=ct(table=252,zone=5002) cookie=0x6900000, duration=5112.299s, table=252, n_packets=19, n_bytes=1862, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,220) cookie=0x8000007, duration=63.123s, table=220, n_packets=8, n_bytes=1160, priority=7,reg6=0x70000300actions=output:6
Broadcast¶
Across hypervisors¶
The ARP broadcast by the VM will be a (local + remote) broadcast.
For the local broadcast on the VM’s OVS itself, the packet will continue to get flooded to all the VM ports by setting the destination LPort tag in the local broadcast group. Hence, there are no explicit pipeline changes for when a packet is transmitted within the source OVS via a local broadcast.
The changes in pipeline for the remote broadcast are illustrated below:
Ingress OVS
Instead of setting the ELAN tag, network VNI will be set in the
tun_idfield as part of bucket actions in remote broadcast group while egressing the packet on the tunnel port.The modifications in flows and groups on the ingress OVS are illustrated below:
cookie=0x8000000, duration=65.484s, table=0, n_packets=23, n_bytes=2016, priority=4,in_port=6actions=write_metadata:0x30000000000/0xffffff0000000001,goto_table:17 cookie=0x6900000, duration=63.106s, table=17, n_packets=23, n_bytes=2016, priority=1,metadata=0x30000000000/0xffffff0000000000 actions=write_metadata:0x2000030000000000/0xfffffffffffffffe,goto_table:40 cookie=0x6900000, duration=64.135s, table=40, n_packets=4, n_bytes=392, priority=61010,ip,dl_src=fa:16:3e:86:59:fd,nw_src=12.1.0.4 actions=ct(table=41,zone=5002) cookie=0x6900000, duration=5112.542s, table=41, n_packets=21, n_bytes=2058, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,17) cookie=0x8040000, duration=62.125s, table=17, n_packets=15, n_bytes=854, priority=6,metadata=0x6000030000000000/0xffffff0000000000 actions=write_metadata:0x700003138a000000/0xfffffffffffffffe,goto_table:48 cookie=0x8500000, duration=5113.124s, table=48, n_packets=24, n_bytes=3044, priority=0 actions=resubmit(,49),resubmit(,50) cookie=0x805138a, duration=62.163s, table=50, n_packets=15, n_bytes=854, priority=20,metadata=0x3138a000000/0xfffffffff000000,dl_src=fa:16:3e:86:59:fd actions=goto_table:51 cookie=0x8030000, duration=5112.911s, table=51, n_packets=18, n_bytes=2568, priority=0 actions=goto_table:52 cookie=0x870138a, duration=62.163s, table=52, n_packets=9, n_bytes=378, priority=5,metadata=0x138a000000/0xffff000001 actions=write_actions(group:210004) group_id=210004,type=all,bucket=actions=group:210003,bucket=actions=set_field:**0x710**->tun_id,output:1
Egress OVS
On the egress OVS, for the packets coming in via the internal VxLAN tunnel (OVS - OVS),
INTERNAL_TUNNEL_TABLEcurrently matches on ELAN tag for broadcast packets. Since the incoming packets will now contain the network VNI in the VxLAN header, theINTERNAL_TUNNEL_TABLEwill match on this VNI, set the ELAN tag in the metadata and forward the packet toL2_DMAC_FILTER_TABLEto be broadcasted via the local broadcast groups traversing the ELAN pipeline.The
TUNNEL_INGRESS_BITbeing set in theCLASSIFIER_TABLE(table 0) ensures that the packet is always sent to the local broadcast group only and hence, remains within the OVS. This is necessary to avoid switching loop back to the source OVS.The modifications in flows and groups on the egress OVS are illustrated below:
cookie=0x8000001, duration=5136.996s, table=0, n_packets=12601, n_bytes=899766, priority=5,in_port=1,actions=write_metadata:0x10000000001/0xfffff0000000001,goto_table:36 cookie=0x9000004, duration=1145.594s, table=36, n_packets=15, n_bytes=476, priority=5,**tun_id=0x710,actions=write_metadata:0x138a000001/0xfffffffff000000,goto_table:51** cookie=0x8030000, duration=5137.609s, table=51, n_packets=9, n_bytes=1293, priority=0 actions=goto_table:52 cookie=0x870138a, duration=1145.592s, table=52, n_packets=0, n_bytes=0, priority=5,metadata=0x138a000001/0xffff000001 actions=apply_actions(group:210003) group_id=210003,type=all,bucket=actions=set_field:0x4->tun_id,resubmit(,55) cookie=0x8800004, duration=1145.594s, table=55, n_packets=9, n_bytes=378, priority=9,tun_id=0x4,actions=load:0x400->NXM_NX_REG6[],resubmit(,220) cookie=0x6900000, duration=63.122s, table=220, n_packets=9, n_bytes=1160, priority=6,reg6=0x300actions=load:0x70000300->NXM_NX_REG6[],write_metadata:0x7000030000000000/0xfffffffffffffffe,goto_table:251 cookie=0x6900000, duration=65.479s, table=251, n_packets=8, n_bytes=392, priority=61010,ip,dl_dst=fa:16:3e:86:59:fd,nw_dst=12.1.0.4 actions=ct(table=252,zone=5002) cookie=0x6900000, duration=5112.299s, table=252, n_packets=19, n_bytes=1862, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,220) cookie=0x8000007, duration=63.123s, table=220, n_packets=8, n_bytes=1160, priority=7,reg6=0x70000300actions=output:6
The ARP response will be a unicast packet, and as indicated above, for unicast packets, there are no explicit pipeline changes.
L3 Forwarding¶
Between VMs on a single OVS¶
There are no explicit pipeline changes for this use-case.
The destination LPort tag will continue to be set in the nexthop group since when
The EGRESS_DISPATCHER_TABLE sends the packet to EGRESS_ACL_TABLE, it is used by the ACL
service.
Between VMs on two different OVS¶
L3 forwarding between VMs on two different hypervisors is asymmetric forwarding since the traffic is routed in the source OVS datapath while it is switched over the wire and then all the way to the destination VM on the destination OVS datapath.
VM sourcing the traffic (Ingress OVS)¶
L3_FIB_TABLE will set the destination network VNI in the tun_id field instead of the MPLS
label.
CLASSIFIER_TABLE => DISPATCHER_TABLE => INGRESS_ACL_TABLE =>
DISPATCHER_TABLE => L3_GW_MAC_TABLE =>
L3_FIB_TABLE (set destination MAC, **set tunnel-ID as destination network VNI**)
=> Output to tunnel port
The modifications in flows and groups on the ingress OVS are illustrated below:
cookie=0x8000000, duration=128.140s, table=0, n_packets=25, n_bytes=2716, priority=4,in_port=5 actions=write_metadata:0x50000000000/0xffffff0000000001,goto_table:17
cookie=0x8000000, duration=4876.599s, table=17, n_packets=0, n_bytes=0, priority=0,metadata=0x5000000000000000/0xf000000000000000 actions=write_metadata:0x6000000000000000/0xf000000000000000,goto_table:80
cookie=0x1030000, duration=4876.563s, table=80, n_packets=0, n_bytes=0, priority=0 actions=resubmit(,17)
cookie=0x6900000, duration=123.870s, table=17, n_packets=25, n_bytes=2716, priority=1,metadata=0x50000000000/0xffffff0000000000 actions=write_metadata:0x2000050000000000/0xfffffffffffffffe,goto_table:40
cookie=0x6900000, duration=126.056s, table=40, n_packets=15, n_bytes=1470, priority=61010,ip,dl_src=fa:16:3e:63:ea:0c,nw_src=10.1.0.4 actions=ct(table=41,zone=5001)
cookie=0x6900000, duration=4877.057s, table=41, n_packets=17, n_bytes=1666, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,17)
cookie=0x6800001, duration=123.485s, table=17, n_packets=28, n_bytes=3584, priority=2,metadata=0x2000050000000000/0xffffff0000000000 actions=write_metadata:0x5000050000000000/0xfffffffffffffffe,goto_table:60
cookie=0x6800000, duration=3566.900s, table=60, n_packets=24, n_bytes=2184, priority=0 actions=resubmit(,17)
cookie=0x8000001, duration=123.456s, table=17, n_packets=17, n_bytes=1554, priority=5,metadata=0x5000050000000000/0xffffff0000000000 actions=write_metadata:0x60000500000222e0/0xfffffffffffffffe,goto_table:19
cookie=0x8000009, duration=124.815s, table=19, n_packets=15, n_bytes=1470, priority=20,metadata=0x222e0/0xfffffffe,dl_dst=fa:16:3e:51:da:ee actions=goto_table:21
cookie=0x8000003, duration=125.568s, table=21, n_packets=9, n_bytes=882, priority=42,ip,metadata=0x222e0/0xfffffffe,nw_dst=12.1.0.3 actions=**set_field:0x710->tun_id**,set_field:fa:16:3e:31:fb:91->eth_dst,output:1
VM receiving the traffic (Egress OVS)¶
On the egress OVS, for the packets coming in via the VxLAN tunnel, INTERNAL_TUNNEL_TABLE
currently matches on MPLS label and sends it to the nexthop group to be taken to the destination
VM via EGRESS_ACL_TABLE.
Since the incoming packets will now contain network VNI in the VxLAN header, the INTERNAL_TUNNEL_TABLE
will match on the VNI, set the ELAN tag in the metadata and forward the packet to
L2_DMAC_FILTER_TABLE, from where it will be taken to the destination VM via the ELAN pipeline.
CLASSIFIER_TABLE => INTERNAL_TUNNEL_TABLE (Match on network VNI, set ELAN tag in the metadata)
=> L2_DMAC_FILTER_TABLE (Match on destination MAC) => EGRESS_DISPATCHER_TABLE
=> EGRESS_ACL_TABLE => Output to destination VM port
The modifications in flows and groups on the egress OVS are illustrated below:
cookie=0x8000001, duration=4918.647s, table=0, n_packets=12292, n_bytes=877616, priority=5,in_port=1actions=write_metadata:0x10000000001/0xfffff0000000001,goto_table:36
cookie=0x9000004, duration=927.245s, table=36, n_packets=8234, n_bytes=52679, priority=5,**tun_id=0x710,actions=write_metadata:0x138a000001/0xfffffffff000000,goto_table:51**
cookie=0x803138a, duration=62.163s, table=51, n_packets=9, n_bytes=576, priority=20,metadata=0x138a000001/0xffff000000,dl_dst=fa:16:3e:86:59:fd actions=load:0x300->NXM_NX_REG6[],resubmit(,220)
cookie=0x6900000, duration=63.122s, table=220, n_packets=9, n_bytes=1160, priority=6,reg6=0x300actions=load:0x70000300->NXM_NX_REG6[],write_metadata:0x7000030000000000/0xfffffffffffffffe,goto_table:251
cookie=0x6900000, duration=65.479s, table=251, n_packets=8, n_bytes=392, priority=61010,ip,dl_dst=fa:16:3e:86:59:fd,nw_dst=12.1.0.4 actions=ct(table=252,zone=5002)
cookie=0x6900000, duration=5112.299s, table=252, n_packets=19, n_bytes=1862, priority=62020,ct_state=-new+est-rel-inv+trk actions=resubmit(,220)
cookie=0x8000007, duration=63.123s, table=220, n_packets=8, n_bytes=1160, priority=7,reg6=0x70000300actions=output:6
NAT Service¶
For NAT, we need VNIs to be used in two scenarios:
- When packet is forwarded from non-NAPT to NAPT hypervisor (VNI per router)
- Between hypervisors (intra DC) over Internet VPN (VNI per Internet VPN)
Hence, a pool titled opendaylight-vni-ranges, non-overlapping with the OpenStack Neutron
vni_ranges configuration, needs to be configured by the OpenDaylight Controller Administrator.
This opendaylight-vni-ranges pool will be used to carve out a unique VNI per router to be then
used in the datapath for traffic forwarding from non-NAPT to NAPT switch for this router.
Similarly, for MPLSOverGRE based external networks, the opendaylight-vni-ranges pool will be
used to carve out a unique VNI per Internet VPN (GRE-provider-type) to be then used in the
datapath for traffic forwarding for SNAT-to-DNAT and DNAT-to-DNAT cases within the
DataCenter. Only one external network can be associated to Internet VPN today and this spec
doesn’t attempt to address that limitation.
A NeutronVPN configuration API will be exposed to the administrator to configure the lower and higher limit for this pool. If the administrator doesn’t configure this explicitly, then the pool will be created with default values of lower limit set to 70000 and upper limit set to 100000, during the first NAT session configuration.
FIB Manager changes: For external network of type GRE, it is required to use
Internet VPN VNI for intra-DC communication, but we still require MPLS labels to reach
SNAT/DNAT VMs from external entities via MPLSOverGRE. Hence, we will make use of the l3vni
attribute added to fibEntries container as part of EVPN_RT5 spec. NAT will populate both
label and l3vni values for fibEntries created for floating-ips and external-fixed-ips with
external network of type GRE. This l3vni value will be used while programming remote FIB flow
entries (on all the switches which are part of the same VRF). But still, MPLS label will be used
to advertise prefixes and in L3_LFIB_TABLE taking the packet to INBOUND_NAPT_TABLE and
PDNAT_TABLE.
For SNAT/DNAT use-cases, we have following provider network types for External Networks:
- VLAN - not VNI based
- Flat - not VNI based
- VxLAN - VNI based (covered by the EVPN_RT5 spec)
- GRE - not VNI based (will continue to use
MPLS labels)
Inter DC¶
SNAT¶
From a VM on a NAPT switch to reach Internet, and reverse traffic reaching back to the VM
There are no explicit pipeline changes.
From a VM on a non-NAPT switch to reach Internet, and reverse traffic reaching back to the VM
On the non-NAPT switch,
PSNAT_TABLE(table 26) will be set withtun_idfield asRouter Based VNIallocated from the pool and send to group to reach NAPT switch.On the NAPT switch,
INTERNAL_TUNNEL_TABLE(table 36) will match on thetun_idfield which will beRouter Based VNIand send the packet toOUTBOUND_NAPT_TABLE(table 46) for SNAT Translation and to be taken to Internet.Non-NAPT switch
cookie=0x8000006, duration=2797.179s, table=26, n_packets=47, n_bytes=3196, priority=5,ip,metadata=0x23a50/0xfffffffe actions=**set_field:0x710->tun_id**,group:202501 group_id=202501,type=all,bucket=actions=output:1
NAPT switch
cookie=0x8000001, duration=4918.647s, table=0, n_packets=12292, n_bytes=877616, priority=5,in_port=1,actions=write_metadata:0x10000000001/0xfffff0000000001,goto_table:36 cookie=0x9000004, duration=927.245s, table=36, n_packets=8234, n_bytes=52679, priority=10,ip,**tun_id=0x710**,actions=write_metadata:0x23a50/0xfffffffe,goto_table:46
As part of the response from NAPT switch, the packet will be taken to the Non-NAPT switch after SNAT reverse translation using destination VMs Network VNI.
Intra DC¶
- VLAN Provider External Networks: VNI is not applicable on the external VLAN Provider network. However, the Router VNI will be used for datapath traffic from non-NAPT switch to NAPT-switch over the internal VxLAN tunnel.
- VxLAN Provider External Networks:
- Explicit creation of Internet VPN: An L3VNI, mandatorily falling within the
opendaylight-vni-ranges, will be provided by the Cloud admin (or tenant). This VNI will be used uniformly for all packet transfer over the VxLAN wire for this Internet VPN (uniformly meaning all the traffic on Internal or External VXLAN Tunnel, except the non-NAPT to NAPT communication). This usecase is covered by EVPN_RT5 spec - No explicit creation of Internet VPN: A transparent Internet VPN having UUID same as that of the corresponding external network UUID is created implicitly and the VNI configured for this external network should be used on the VxLAN wire. This usecase is out of scope from the perspective of this spec, and the same is indicated in Out of Scope section.
- Explicit creation of Internet VPN: An L3VNI, mandatorily falling within the
- GRE Provider External Networks:
Internet VPN VNIwill be carved per Internet VPN usingopendaylight-vni-rangesto be used on the wire.
DNAT to DNAT¶
FIP VM to FIP VM on different hypervisors
After DNAT translation on the first hypervisor
DNAT-OVS-1, the traffic will be sent to theL3_FIB_TABLE(table=21) in order to reach the floating IP VM on the second hypervisorDNAT-OVS-2. Here, thetun_idaction field will be set as theINTERNET VPN VNIvalue.DNAT-OVS-1
cookie=0x8000003, duration=518.567s, table=21, n_packets=0, n_bytes=0, priority=42,ip,metadata=0x222e8/0xfffffffe,nw_dst=172.160.0.200 actions=**set_field:0x11178->tun_id**,output:9DNAT-OVS-2
cookie=0x9011177, duration=411685.075s, table=36, n_packets=2, n_bytes=196, priority=**6**,**tun_id=0x11178**actions=resubmit(,25) cookie=0x9011179, duration=478573.171s, table=36, n_packets=2, n_bytes=140, priority=5,**tun_id=0x11178**,actions=goto_table:44 cookie=0x8000004, duration=408145.805s, table=25, n_packets=600, n_bytes=58064, priority=10,ip,nw_dst=172.160.0.100,**eth_dst=fa:16:3e:e6:e3:c6** actions=set_field:10.0.0.5->ip_dst,write_metadata:0x222e0/0xfffffffe,goto_table:27 cookie=0x8000004, duration=408145.805s, table=25, n_packets=600, n_bytes=58064, priority=10,ipactions=goto_table:44
First, the
INTERNAL_TUNNEL_TABLE(table=36) will take the packet to thePDNAT_TABLE(table 25) for an exact FIP match inPDNAT_TABLE.- In case of a successful FIP match,
PDNAT_TABLEwill further match on floating IP MAC. This is done as a security prerogative since in DNAT usecases, the packet can land to the hypervisor directly from the external world. Hence, better to have a second match criteria. - In case of no match, the packet will be redirected to the SNAT pipeline towards the
INBOUND_NAPT_TABLE(table=44). This is the use-case whereDNAT-OVS-2also acts as the NAPT switch.
In summary, on an given NAPT switch, if both DNAT and SNAT are configured, the incoming traffic will first be sent to the
PDNAT_TABLEand if there is no FIP match found, then it will be forwarded toINBOUND_NAPT_TABLEfor SNAT translation.As part of the response, the
Internet VPN VNIwill be used astun_idto reach floating IP VM onDNAT-OVS-1.FIP VM to FIP VM on same hypervisor
The pipeline changes will be similar as are for different hypervisors, the only difference being that
INTERNAL_TUNNEL_TABLEwill never be hit in this case.
SNAT to DNAT¶
Non-FIP VM to FIP VM on different hypervisors (with NAPT elected as the FIP VM hypervisor)
The packet will be sent to the NAPT hypervisor from non-FIP VM (for SNAT translation) using
Router VNI(similar to as described in SNAT section). As part of the response from the NAPT switch after SNAT reverse translation, the packet is forwarded to non-FIP VM using destination VM’s Network VNI.Non-FIP VM to FIP VM on the same NAPT hypervisor
There are no explicit pipeline changes for this use-case.
Non-FIP VM to FIP VM on the same hypervisor, but a different hypervisor elected as NAPT switch
NAPT hypervisor
The packet will be sent to the NAPT hypervisor from non-FIP VM (for SNAT translation) using
Router VNI(similar to as described in SNAT section). On the NAPT switch, theINTERNAL_TUNNEL_TABLEwill match on theRouter VNIin thetun_idfield and send the packet toOUTBOUND_NAPT_TABLEfor SNAT translation (similar to as described in SNAT section).cookie=0x8000005, duration=5073.829s, table=36, n_packets=61, n_bytes=4610, priority=10,ip,**tun_id=0x11170**,actions=write_metadata:0x222e0/0xfffffffe,goto_table:46The packet will later be sent back to the FIP VM hypervisor from L3_FIB_TABLE with
tun_idfield set as theInternet VPN VNI.cookie=0x8000003, duration=518.567s, table=21, n_packets=0, n_bytes=0, priority=42,ip,metadata=0x222e8/0xfffffffe,nw_dst=172.160.0.200 actions=**set_field:0x11178->tun_id**,output:9FIP VM hypervisor
On reaching the FIP VM Hypervisor, the packet will be sent for DNAT translation. The
INTERNAL_TUNNEL_TABLEwill match on theInternet VPN VNIin thetun_idfield and send the packet toPDNAT_TABLE.cookie=0x9011177, duration=411685.075s, table=36, n_packets=2, n_bytes=196, priority=**6**,**tun_id=0x11178**,actions=resubmit(,25) cookie=0x8000004, duration=408145.805s, table=25, n_packets=600, n_bytes=58064, priority=10,ip,nw_dst=172.160.0.100,**eth_dst=fa:16:3e:e6:e3:c6** actions=set_field:10.0.0.5->ip_dst,write_metadata:0x222e0/0xfffffffe,goto_table:27
Upon FIP VM response, DNAT reverse translation happens and traffic is sent back to the NAPT switch for SNAT translation. The
L3_FIB_TABLEwill be set withInternet VPN VNIin thetun_idfield.cookie=0x8000003, duration=95.300s, table=21, n_packets=2, n_bytes=140, priority=42,ip,metadata=0x222ea/0xfffffffe,nw_dst=172.160.0.3 actions=**set_field:0x11178->tun_id**,output:5NAPT hypervisor
On NAPT hypervisor, the
INTERNAL_TUNNEL_TABLEwill match on theInternet VPN VNIin thetun_idfield and send the packet to `` INBOUND_NAPT_TABLE`` for SNAT reverse translation (external fixed IP to VM IP). The packet will then be sent back to the non-FIP VM using destination VM’s Network VNI.
Non-FIP VM to FIP VM on different hypervisors (with NAPT elected as the non-FIP VM hypervisor)
After SNAT Translation,
Internet VPN VNIwill be used to reach FIP VM. On FIP VM hypervisor, theINTERNAL_TUNNEL_TABLEwill take the packet to thePDNAT_TABLEto match onInternet VPN VNIin thetun_idfield for DNAT translation.Upon response from FIP, DNAT reverse translation happens and uses
Internet VPN VNIto reach back to the non-FIP VM.
YANG changes¶
opendaylight-vni-rangesandenforce-openstack-semanticsleaf elements will be added to neutronvpn-config container inneutronvpn-config.yang:opendaylight-vni-rangeswill be introduced to accept inputs for the VNI range pool from the configurator via the corresponding exposed REST API. In case this is not defined, the default value defined innetvirt-neutronvpn-config.xmlwill be used to create this pool.enforce-openstack-semanticswill be introduced to have the flexibility to enable or disable OpenStack semantics in the dataplane for this feature. It will be defaulted to true, meaning these semantics will be enforced by default. In case it is set to false, the dataplane will continue to be programmed with LPort tags / ELAN tags for switching and with labels for routing use-cases. Once this feature gets stabilized and the semantics are in place to use VNIs on the wire for BGPVPN based forwarding too, this config can be permanently removed if deemed fit.neutronvpn-config.yang¶container neutronvpn-config { config true; ... ... leaf opendaylight-vni-ranges { type string; default "70000:99999"; } leaf enforce-openstack-semantics { type boolean; default true; } }
Provider network-type and provider segmentation-ID need to be propagated to FIB Manager to manipulate flows based on the same. Hence:
A new grouping
network-attributeswill be introduced inneutronvpn.yangto hold network type and segmentation ID. This grouping will replace the leaf-nodenetwork-idinsubnetmapsMD-SAL configuration datastore:neutronvpn.yang¶grouping network-attributes { leaf network-id { type yang:uuid; description "UUID representing the network"; } leaf network-type { type enumeration { enum "FLAT"; enum "VLAN"; enum "VXLAN"; enum "GRE"; } } leaf segmentation-id { type uint32; description "Optional. Isolated segment on the physical network. If segment-type is vlan, this ID is a vlan identifier. If segment-type is vxlan, this ID is a vni. If segment-type is flat/gre, this ID is set to 0"; } } container subnetmaps { ... ... uses network-attributes; }
These attributes will be propagated upon addition of a router-interface or addition of a subnet to a BGPVPN to VPN Manager module via the
subnet-added-to-vpnnotification modelled inneutronvpn.yang. Hence, the following node will be added:neutronvpn.yang¶notification subnet-added-to-vpn { description "new subnet added to vpn"; ... ... uses network-attributes; }VpnSubnetRouteHandler will act on these notifications and store these attributes in
subnet-op-dataMD-SAL operational datastore as described below. FIB Manager will get to retrieve thesubnetIDfrom the primary adjacency of the concerned VPN interface. ThissubnetIDwill be used as the key to retrievenetwork-attributesfromsubnet-op-datadatastore.odl-l3vpn.yang¶import neutronvpn { prefix nvpn; revision-date "2015-06-02"; } container subnet-op-data { ... ... uses nvpn:network-attributes; }
subnetIDandnat-prefixleaf elements will be added toprefix-to-interfacecontainer inodl-l3vpn.yang:- For NAT use-cases where the VRF entry is not always associated with a VPN interface (eg. for
NAT entries such as floating IP and router-gateway-IPs for external VLAN / flat networks),
subnetIDleaf element will be added to make it possible to retrieve thenetwork-attributes. - To distinguish a non-NAT prefix from a NAT prefix,
nat-prefixleaf element will be added. This is a boolean attribute indicating whether the prefix is a NAT prefix (meaning a floating IP, or an external-fixed-ip of a router-gateway). The VRFEntry corresponding to the NAT prefix entries here may carry both theMPLS labeland theInternet VPN VNI. For SNAT-to-DNAT within the datacenter, where the Internet VPN contains an MPLSOverGRE based external network, this VRF entry will publish theMPLS labelto BGP while theInternet VPN VNI(also known asL3VNI) will be used to carry intra-DC traffic on the external segment within the datacenter.
odl-l3vpn.yang¶container prefix-to-interface { config false; list vpn-ids { key vpn-id; leaf vpn-id {type uint32;} list prefixes { key ip_address; ... ... leaf subnet-id { type yang:uuid; } leaf nat-prefix { type boolean; default false; } } } }- For NAT use-cases where the VRF entry is not always associated with a VPN interface (eg. for
NAT entries such as floating IP and router-gateway-IPs for external VLAN / flat networks),
Configuration impact¶
- We have to make sure that we do not accept configuration of VxLAN type provider networks without
the
segmentation-IDavailable in them since we are using it to represent the VNI on the wire and in the flows/groups.
Clustering considerations¶
No specific additional clustering considerations to be adhered to.
Security considerations¶
None.
Targeted Release(s)¶
Carbon.
Known Limitations¶
None.
Alternatives¶
N.A.
Usage¶
Features to Install¶
odl-netvirt-openstack
Implementation¶
Assignee(s)¶
- Primary assignee:
- Abhinav Gupta <abhinav.gupta@ericsson.com> Vivekanandan Narasimhan <n.vivekanandan@ericsson.com>
- Other contributors:
- Chetan Arakere Gowdru <chetan.arakere@altencalsoftlabs.com> Karthikeyan Krishnan <karthikeyan.k@altencalsoftlabs.com> Yugandhar Sarraju <yugandhar.s@altencalsoftlabs.com>
Work Items¶
- Code changes to alter the pipeline and e2e testing of the use-cases mentioned.
- Add Documentation
Dependencies¶
This doesn’t add any new dependencies.
Testing¶
Unit Tests¶
Appropriate UTs will be added for the new code coming in once framework is in place.
Integration Tests¶
There won’t be any Integration tests provided for this feature.
Documentation Impact¶
This will require changes to the Developer Guide.
Developer Guide needs to capture how this feature modifies the existing Netvirt L3 forwarding service implementation.